Product Classification

Product Type Wireless and radiating connector
Product Brand HELIAX®
Product Series LDF4-50A
Ordering Note CommScope® standard product (Global)
Warranty Five years

General Specifications

Body Style Straight
Cable Family LDF4-50A
Inner Contact Attachment Method Captivated
Inner Contact Plating Silver
Interface 7-16 DIN Female
Mounting Angle Straight
Outer Contact Attachment Method Clamp
Outer Contact Plating Trimetal

Dimensions

Length 63 mm | 2.480 in
Diameter 29 mm | 1.142 in
Nominal Size 1/2 in

Outline Drawing

Click on image to enlarge.

Electrical Specifications

3rd Order IMD at Frequency -120 dBm @ 900 MHz
3rd Order IMD Dynamic Test Method Tapping/Impact, no rotation
3rd Order IMD Dynamic, typical -97 dBm
3rd Order IMD Test Method Two +43 dBm carriers
Insertion Loss Coefficient, typical 0.05
Average Power at Frequency 1.1 kW @ 900 MHz
Cable Impedance 50 ohm
Connector Impedance 50 ohm
dc Test Voltage 4000 V
Impedance 50 ohm
Inner Contact Resistance, maximum 0.4 mOhm
Insulation Resistance, minimum 10000 mOhm
Operating Frequency Band 0 – 7500 MHz
Outer Contact Resistance, maximum 1.5 mOhm
RF Operating Voltage, maximum (vrms) 1415 V

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB) Gated VSWR Gated Return Loss (dB) VSWR, typical Return Loss, typical (dB)
0–1000 MHz 1.060 30.70 1.023 39.00
1000–2200 MHz 1.120 24.94 1.036 35.00
2200–3000 MHz 1.150 23.13 1.041 34.00
3000–4000 MHz 1.200 20.83 1.041 34.00
4000–6000 MHz 1.250 19.08 1.065 30.00
6000–7500 MHz 1.119 25.00 1.484 14.20
7000–8800 MHz 1.253 19.00 1.484 14.20

Mechanical Specifications

Attachment Durability 25 cycles
Connector Retention Tensile Force 600 N | 134.885 lbf
Connector Retention Torque 4.5 N-m | 39.828 in lb
Insertion Force 200 N | 44.962 lbf
Insertion Force Method IEC 61169-4:9.3.5
Interface Durability 500 cycles
Interface Durability Method IEC 61169-4:9.5
Mechanical Shock Test Method IEC 60068-2-27

Environmental Specifications

Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Corrosion Test Method IEC 60068-2-11
Immersion Depth 1 m
Immersion Test Mating Mated
Immersion Test Method IEC 60529:2001, IP68
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6